TEKTRONIX TM503 Power Module Mainframe w/3 PlugIn Modules (FG501A-DM501A-DC503A) For Sale

TEKTRONIX TM503 Power Module Mainframe w/3 PlugIn Modules (FG501A-DM501A-DC503A)


Buy Now

TEKTRONIX TM503 Power Module Mainframe w/3 PlugIn Modules (FG501A-DM501A-DC503A):
$575.00

Selling the pictured TEKTRONIC TM503 Power Module Mainframe and TM500 Series Plug-In Modules(FG501A-DM501A-DC503A), with power cord. Operative; powers on.

The Following Components are Included in This Sale:

  • One Tektronix TM503 3-Slot Power Module Mainframe, with power cord.
  • (Module Slot 1) Tektronix FG 501A 2MHz Function Generator
  • (Module Slot 2) Tektronix DM 501A Digital Multimeter
  • (Module Slot 3) Tektronix DC 503A Universal Counter/Timer

Items will be shipped as a Set exactly as pictured in this listing, and described above. Shipping is free and all items in this Set will be appropriately packaged and shipped to you using the fastest possible method. Most items are shipped the same day from my shop in the southeastern U.S.

Here are Tektronic\'s Features and Product Details:

The Tektronix TM503 is a three-slot-wide power module compatible with all TM500-Series plug-ins. Up to three single width modules can be plugged into the TM503, or one single and one double width module can be style=\"margin: 0px; font-stretch: normal; line-height: normal;\">TM503 Mainframe with 3 Plug-In Modules

  • 1.2 AMP
  • 60 HZ
  • 120 VAC
  • 120 W
  • Total Weight (Mainframe + 3 Modules): 30 lbs
  • Product Details:

    FG501

    • Frequency: 0.01 Hz to 1MHz in decade steps
    • Output: Max. 20 Vp-p into high impedance, 10 V into 50 Ω (SN < B130000: 15/7.5 V)
    • Offset: Max. ±7.5 Vp-p into high impedance, 5 V into 50 Ω (SN < B130000: 5/2.5 V


    DM501

    • DC V ranges: 200 mV, 2 V, 20 V, 200 V, 1000 V
    • DC V accuracy: 0.05% of reading + 0.01% FS in 2 V to 200 V ranges @ +18 °C to +28 °C
    • DC V input resistance: 10 MΩ
    • AC V ranges: 200 mV, 2 V, 20 V, 200 V, 500 V
    • AC V accuracy: 0.6% of reading + 0.05% FS in 0.2 V to 200 V ranges, 40 Hz to 10 kHz @ +18 °C to +28 °C
    • AC V input resistance: 10 MΩ // 160 pF
    • dB ranges (DM501A only): −40, −20, 0, +20, +40 dB
    • Ω ranges: 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ
    • Ω accuracy: 0.15% of reading + 0.015% FS, 200 Ω to 2 MΩ ranges @ +18 °C to +28 °C
    • DC A ranges: 200 μA, 2 mA, 20 mA, 200 mA, 2 A
    • DC A accuracy: 0.2% of reading + 0.015% FS @ +18 °C to +28 °C
    • AC A ranges: 200 μA, 2 mA, 20 mA, 200 mA, 2 A
    • AC A accuracy: 0.6% of reading + 0.05% FS, 20 Hz to 10 kHz @ +18 °C to +28 °C
    • Temperature range: −62 °C to +240 °C
    • Temperature accuracy: ±2 °C from -62 °C to +150 °C with probe calibrated to instrument, @ +18 °C to +28 °C ambient

    DC503

    • As powered by the Tektronix TM503 Mainframe included here the Tektronix DC 503A Universal Counter/Timer instrument meets the sensitivity specification: 35 mVrms @ 120MHz.


    Buy Now


    Fatal error: Call to undefined function MagicParser_parse() in /home/leenooks/public_html/store/relateditems.php on line 73